grease interceptor installation detailgeelong cats coaching staff 2022

Subscribe to the NY Engineers Blog below. %%EOF 2 0 obj Each manhole access shall be minimum 20" diameter clear opening. Armatherm Thermal Bridging Solutions . Available in sizes from 50 gallons all the way to 2,000 gallons. Houston, TX 77040 For more information on product availability call (888) 965-3227 today. >> ArborJet | Ecologel NutriRoot - Tree Planting with NutriRoot Installation Download DWG. 816-GGI-5000 Grease Interceptor 5,000 Gal. PGIs are designed to remove large quantities of sewer-clogging fats, oils, and grease before it's discharged into a municipal wastewater treatment system. The proposed system must deliver equivalent or superior performance compared with a grease interceptor. They are very important for public hygiene, and the NYC Dept. ANCHOR KIT INSTALLATION DETAIL 2-1/2" Minimum Insertion Depth 4" Maximum Insertion Depth (into GB unit only) FIELD CUT RISER (24 SERIES) INSTALLATION GUIDELINES Tools needed: 7/16" Nut driver tool/bit (included), marker (included), tape Installation of Grease Interceptors. The grease interceptor shall be constructed with a minimum of two baffles. For this reason, they are also known as grease traps. Other. Cleaning (5000 and 5100 Series) The frequency of cleaning is determined by the use load factor and the capacity of the installed interceptor. Access Access requirements shall follow WSSC Code 302.10.1/1003.6.2.6 & 1003.6.2.7 and WSSC Standard Details. The retaining capacity is calculated separately for the fixtures in each table and the two values are then added. The interceptor must be cleaned whenever 25 percent of any chamber becomes filled with FOG or solids. In addition to NYC-specific requirements, grease interceptors are subject to national standards such as: The first step to specify grease interceptors is reviewing the kitchen layout and determining which equipment must be routed to grease traps. <>>> Call 1-800-541-8004 for more information . Tab will move on to the next part of the site rather than go through menu items. Sizing - PDI Method Using Sink Dimensions. ?h_ Ode'3|y 4!f/?[f endstream endobj 72 0 obj 158 endobj 31 0 obj << /Type /Page /Parent 17 0 R /Resources 32 0 R /Contents [ 45 0 R 47 0 R 49 0 R 51 0 R 53 0 R 55 0 R 57 0 R 59 0 R ] /MediaBox [ 0 0 612 783 ] /CropBox [ 0 0 612 783 ] /Rotate 0 >> endobj 32 0 obj << /ProcSet [ /PDF /Text ] /Font << /F2 43 0 R /F3 40 0 R /F4 36 0 R /F5 33 0 R /F6 42 0 R >> /ExtGState << /GS1 63 0 R /GS2 64 0 R >> /ColorSpace << /DefaultCMYK 41 0 R /Cs9 41 0 R >> /Properties << /MC1 68 0 R /MC2 69 0 R /MC3 70 0 R >> >> endobj 33 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 240 /Widths [ 240 258 407 480 480 759 556 240 241 241 352 600 240 352 240 278 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 444 800 500 519 519 556 463 444 537 537 204 426 500 444 704 556 556 481 556 519 500 463 519 462 722 481 462 463 259 278 259 600 500 204 444 463 426 463 444 259 463 463 204 204 444 204 722 463 444 463 463 296 407 259 463 406 648 406 406 389 259 222 259 600 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 480 480 0 0 0 0 0 800 0 0 0 240 0 0 240 600 240 240 0 463 240 240 240 240 240 0 0 240 0 0 0 0 0 240 0 240 240 0 0 0 240 0 0 0 0 0 0 0 407 407 0 240 0 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 ] /Encoding /MacRomanEncoding /BaseFont /MIJNKO+HelveticaNeue-Condensed /FontDescriptor 35 0 R >> endobj 34 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262240 /FontBBox [ -171 -224 1116 961 ] /FontName /MIJNJJ+HelveticaNeue-BoldCondObl /ItalicAngle -12 /StemV 138 /XHeight 538 /CharSet (/Z/T/C/R/D/S/G/U/I/space/L/M/P/N/O/B) /FontFile3 66 0 R >> endobj 35 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 32 /FontBBox [ -164 -212 1000 932 ] /FontName /MIJNKO+HelveticaNeue-Condensed /ItalicAngle 0 /StemV 84 /XHeight 536 /CharSet (/quoteright/m/two/three/o/parenleft/p/a/S/parenright/quotedblleft/four/q\ /five/U/N/B/asterisk/r/T/space/b/V/C/six/seven/s/W/c/d/D/comma/F/t/eight\ /e/E/G/hyphen/u/quotedblright/nine/f/P/I/n/numbersign/v/period/Z/colon/h\ /x/w/slash/i/L/y/zero/j/M/z/g/l/one/k/O/A) /FontFile3 62 0 R >> endobj 36 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 240 296 463 480 480 778 593 260 296 296 390 600 240 370 240 332 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 481 800 556 556 537 574 481 463 556 556 258 463 537 463 740 574 556 519 556 556 519 480 538 519 760 537 520 481 315 332 315 600 500 222 481 500 463 500 463 296 500 500 240 240 500 240 758 500 480 500 500 333 444 296 500 444 704 462 444 426 315 222 315 600 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 480 480 240 240 240 240 240 800 240 240 240 240 240 240 240 600 240 240 240 500 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNJJ+HelveticaNeue-BoldCondObl /FontDescriptor 34 0 R >> endobj 37 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262176 /FontBBox [ -164 -224 1066 961 ] /FontName /MIJNMB+HelveticaNeue-BoldCond /ItalicAngle 0 /StemV 138 /XHeight 538 /CharSet (/quoteright/m/two/three/o/parenleft/R/p/a/S/parenright/four/five/quotele\ ft/U/N/K/B/r/T/space/V/six/C/s/seven/W/d/F/D/comma/c/t/eight/X/e/E/G/hyp\ hen/u/f/P/I/n/Z/h/colon/w/slash/i/L/H/zero/M/z/g/l/one/O/A) /FontFile3 60 0 R >> endobj 38 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 96 /FontBBox [ -171 -212 1068 932 ] /FontName /MIJNJL+HelveticaNeue-CondensedObl /ItalicAngle -12 /StemV 84 /XHeight 536 /CharSet (/two/T/colon/m/C/w/o/R/F/D/comma/c/four/S/E/G/hyphen/z/five/U/I/A/n/peri\ od/six/space/V/r/slash/seven/W/H/eight/zero/X/u/one/nine/P/O/N/B) /FontFile3 67 0 R >> endobj 39 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262240 /FontBBox [ -172 -230 1148 972 ] /FontName /MIJNIH+HelveticaNeue-BlackCondObl /ItalicAngle -12 /StemV 180 /XHeight 541 /CharSet (/T/C/R/E/S/G/I/A/space/P/N/O) /FontFile3 61 0 R >> endobj 40 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 240 /Widths [ 240 296 463 480 480 778 593 260 296 296 390 600 240 370 240 332 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 481 800 556 556 537 574 481 463 556 556 258 463 537 463 740 574 556 519 556 556 519 480 538 519 760 537 520 481 315 332 315 600 500 222 481 500 463 500 463 296 500 500 240 240 500 240 758 500 480 500 500 333 444 296 500 444 704 462 444 426 315 222 315 600 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 480 480 0 0 0 0 0 800 0 0 0 240 0 0 240 600 240 240 0 500 240 240 240 240 240 0 0 240 0 0 0 0 0 240 0 240 240 0 0 0 240 0 0 0 0 0 0 0 0 0 260 260 0 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 ] /Encoding /MacRomanEncoding /BaseFont /MIJNMB+HelveticaNeue-BoldCond /FontDescriptor 37 0 R >> endobj 41 0 obj [ /ICCBased 65 0 R ] endobj 42 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 240 258 407 480 480 759 556 240 241 241 352 600 240 352 240 278 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 444 800 500 519 519 556 463 444 537 537 204 426 500 444 704 556 556 481 556 519 500 463 519 462 722 481 462 463 259 278 259 600 500 204 444 463 426 463 444 259 463 463 204 204 444 204 722 463 444 463 463 296 407 259 463 406 648 406 406 389 259 222 259 600 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 480 480 240 240 240 240 240 800 240 240 240 240 240 240 240 600 240 240 240 463 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNJL+HelveticaNeue-CondensedObl /FontDescriptor 38 0 R >> endobj 43 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 260 314 481 520 520 778 611 260 314 314 406 600 260 368 260 333 520 520 520 520 520 520 520 520 520 520 260 260 600 600 600 500 800 556 574 537 574 500 481 556 574 260 481 556 463 758 592 556 537 556 574 537 462 556 520 778 536 520 481 314 333 314 600 500 260 500 520 481 520 481 315 520 520 258 258 500 258 778 520 500 520 520 352 463 315 520 463 740 481 463 444 333 222 333 600 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 520 520 260 260 260 260 260 800 260 260 260 260 260 260 260 600 260 260 260 520 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNIH+HelveticaNeue-BlackCondObl /FontDescriptor 39 0 R >> endobj 44 0 obj 19558 endobj 45 0 obj << /Filter /FlateDecode /Length 44 0 R >> stream Ashland PolyTrap. Schier grease interceptors are not to be installed in any other manner except as shown. 7. Grease Interceptor Installation Inspections Partial Inspection #1: JCW inspection of the excavation, interceptor, riser (s) and anchor kit (if applicable) is required prior to backfill. P: 972-842-8801, Kimberly JenkinsAtlanta, GAP: 706-506-2805, Impact of Flushable Wipes on Wastewater Treatment. endobj Heavy-duty aluminum overlays are available for high traffic areas. O8qQP Manhole covers shall be placed at grade elevation by using concrete extension rings or 24" RCP. 3920A02. hbbd```b``"A$"ESA0:@o hbHG DL hX <2[ / endstream endobj startxref 0 %%EOF 85 0 obj <>stream If water is present in oil removed through gravity draw-off, ZZY)R! We use cookies to offer you a better browsing experience, analyze site traffic, personalize content, and serve targeted advertisements. On a dishwasher with three tanks, bypass the final rinse cycle when permitted by code. All Rights Reserved. 29 0 obj << /Linearized 1 /O 31 /H [ 1314 270 ] /L 478682 /E 423469 /N 3 /T 477984 >> endobj xref 29 44 0000000016 00000 n 0000001227 00000 n 0000001584 00000 n 0000001791 00000 n 0000002056 00000 n 0000002917 00000 n 0000003213 00000 n 0000003727 00000 n 0000004530 00000 n 0000004991 00000 n 0000005385 00000 n 0000005674 00000 n 0000006532 00000 n 0000006571 00000 n 0000007375 00000 n 0000008179 00000 n 0000008202 00000 n 0000027838 00000 n 0000027861 00000 n 0000046369 00000 n 0000046392 00000 n 0000058652 00000 n 0000058675 00000 n 0000070930 00000 n 0000070953 00000 n 0000083362 00000 n 0000083385 00000 n 0000095676 00000 n 0000095699 00000 n 0000108048 00000 n 0000108071 00000 n 0000121155 00000 n 0000124972 00000 n 0000126110 00000 n 0000130219 00000 n 0000130358 00000 n 0000130496 00000 n 0000418973 00000 n 0000420291 00000 n 0000422991 00000 n 0000423108 00000 n 0000423213 00000 n 0000001314 00000 n 0000001563 00000 n trailer << /Size 73 /Info 28 0 R /Root 30 0 R /Prev 477974 /ID[] >> startxref 0 %%EOF 30 0 obj << /Type /Catalog /Pages 17 0 R /JT 27 0 R /PageLabels 16 0 R >> endobj 71 0 obj << /S 55 /L 179 /Filter /FlateDecode /Length 72 0 R >> stream The use of alternative devices is allowed, as long as the following requirements are met: Grease interceptors perform a fundamental role in commercial kitchens, as well as other applications where significant amounts of grease or oil are discharged. A certain oil content is normal in wastewater, and it forms a thin floating layer once it reaches septic tanks and water treatment facilities. Although the procedure is straightforward, keep in mind that some exceptions apply: A final requirement is that water flowing through a grease interceptor must not have a temperature above 180F. Copyright 2023Zurn Industries, LLC. Make sure your grease interceptors are specified correctly. The vent on the flow control is an air intake. Source: www.drain-tech.com Check Details. An example is the Blakeslee dishwasher with a 3 center line waste outlet and with the new dry recirculating pump which requires that the static water level in the separator be lower than 9. 441 0 obj <>/Filter/FlateDecode/ID[<2699F7281AEA5C4E9D5F13A8D243EA86><15504ED7A2B8C8499534A37D03AF58DB>]/Index[425 30]/Info 424 0 R/Length 92/Prev 293128/Root 426 0 R/Size 455/Type/XRef/W[1 3 1]>>stream Allow headroom to lift out both screens for cleaning. Most local plumbing codes prohibit any industrial user from discharging FOG over 100 mg/l into the public sewer system. Highstrength precast concrete, steel, or fiberglass, Precast concrete, fiberglass, or stainless steel construction, Interior liners include epoxy, high density polyethylene, and stainless steel, Free-standing and direct-bury configurations, Los Angeles, Long Beach, Anaheim, CA - Grease Interceptor GT-500, Austin, Round Rock, Georgetown, Pflugerville, TX - Grease, Wichita Falls, Iowa Park, Burkburnett, TX - Grease Interceptor GT-, San Diego, San Bernadino, Highland, FEWD Program, Carlsbad, CA -, Oceanside, Vista, San Marcos, CA - Grease Interceptor. ]!P8?L r!T!> `OHc?%z$Tk_ Specs and Installation. 4800 series. ParkUSA, a Northwest Pipe Company, provides innovative water, wastewater, and stormwater equipment and technology for infrastructure and built environments. of Environmental Protection. Installation must conform to local code. A good product can have poor performance if it used in the wrong application or installed incorrectly. hb```f``rd`a` @1V 8 noqkE5lb I. B`f?~~u#_'N:pN8.G@;X$ 0A endstream endobj 57 0 obj <> endobj 58 0 obj <> endobj 59 0 obj <>stream STEEL SEPARATORS, INTERCEPTORS,TRENCH DRAINS, & CATCH BASINS. Restaurant Kitchen Stainless Steel Grease Trap Interceptor Silver High-efficient. The retained FOG should be regularly removed or pumped out of the interceptor. They are used to train mechanics, hotels, supermarkets and other Toilet Installation January 19, 2018 %PDF-1.3 % The accumulation of FOG can escalate into blockages and sanitary sewer overflows (SSO) that disrupt wastewater treatment operations and increase costs. More than 10 available. Soup and stock kettles that discharge into a floor drain count towards the Table II aggregate volume, even if floor drains are Table I fixtures. hVnF>Y$FvR5 Z1192 Grease Recovery Appliance. 75 GPM Hydromechanical Grease Interceptor. Each compartment, 18 inches by 18 inches by 8 inches with 1.5-inch sink drain and trap. Maintenance of Grease Inteceptors. Grease rises to the top inside the interceptor and is trapped using a system of baffles. All sizes available for your grease trap needs. Lard and other high-viscosity fats can also solidify as they cool down, trapping other solids and blocking sewage pipes. Select a separator with a gallon-per-minute flow equal to the initial tank discharge capacity. Schier is a privately-owned manufacturer of a premier lineup of 100% USA-made, high-capacity, lifetime guaranteed grease interceptors for commercial kitchens. Grease interceptors are available in recessed, semi-recessed and on-floor versions. The triple outlet feature allows for installation flexibility, including the ability to connect an . Rugged durability to efficiently slow down the flow of waste water and remove grease, fats, and oil byproducts before flowing into a sanitary sewer system; Customizable sectional design; Quick and easy install; Sturdy five-sided watertight design; Customizable with special accesses, block-outs, and knock-outs; Variety of shapes and sizes available Grease Interceptor - Hydromechanical, 4 Thru 100 GPM . Aggregate volume is the maximum volume that can flow through the interceptor simultaneously, determined by adding the wastewater volume of individual fixtures plus any required margins. ,Ma0kiE"[*cb\ivF}ntC~\>a{.6y The GB-250 offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. << /Length 103354 /Filter /FlateDecode /DecodeParms Web grease interceptor sizing and installation guidelines. Using manual valves to reduce flow to a grease interceptor is not allowed. Install outlet tee with 6" diameter vertical riser. hbspt.cta._relativeUrls=true;hbspt.cta.load(2004318, '42988b7d-d06c-4059-82e4-709ad6f267fd', {"useNewLoader":"true","region":"na1"}); For projects in New York City, only a Registered Design Professional (RDP) can submit commercial kitchen plumbing designs for approval by the NYC Department of Buildings, and only a Licensed Master Plumber (LMP) can carry out the actual installation. endobj Solidified grease can cause stoppages downstream in piping systems and create costly and time-consuming problems at municipal wastewater treatment plants. Table I reaches up to 123,000 cubic inches, while Table II reaches up to 61,600 cubic inches. For calculation of grease interceptor retaining capacity, the NYC Department of Environmental Protection provides two tables, each with interceptor capacity values (in pounds) corresponding to aggregate volume from kitchen fixtures (in cubic inches). Gravity Grease Interceptors (GGI), also commonly known as a grease trap, work on the buoyancy principle. 20GPM GREASE INTERCEPTOR 2"SPG. 425 0 obj <> endobj A recommendation not only for grease interceptors but for equipment in general is adhering to manufacturer instructions. Fax: 419-836-4140. %PDF-1.5 6k-p}\;Ku]ge(LYv_En`{2|6&Vd;>x+g=W[!c;^m0xEw!Yf;P4I>d;'3FT4=v&Z[o)kp'/NwG|Wp#_E. In general, grease traps contain baffles with baffles. A certain oil content is normal in wastewater, and it forms a thin floating layer once it reaches septic tanks and water treatment facilities. Hydro Mechanical Grease Interceptors . xT-kofya]`aWCU.;1(cszzy z>C:.?Wo__?~~:Y_xy r3X~~d,-e>W? Press Enter to show all options, press Tab go to next option, Environmental Requirements for Construction Activities, Workers' Compensation Provider Information, Job Descriptions & Pay Plans (not open postings), Valley Cities Affordability & Homeowner's Comparisons, 2022 Mesa Standard Details and Specifications, 2021 Mesa Standard Details and Specifications, 2019 Mesa Standard Details and Specifications, 2022 Engineering and Design Standards Manual, 2022 Updates to the Engineering Design Standards, 2021 Engineering and Design Standards Manual, 2021 Updates to the Engineering and Design Standards, 2019 Engineering and Design Standards Manual, Water Sewer and Storm Drain General Notes [PDF]. GREASE TRAP - an interceptor of at least 125 gallon capacity which is designed and installed so as to separate and retain grease and which is generally installed below grade outdoors with pro- visions for above grade accessibility for cleaning purposes. / 50 gpm item description recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared. 5 - Grease Trap at Grocery Store Deli Drain Pros 129K views 3 years ago What Is That. Assume the aggregate volume is 3,000 cubic inches for Table I fixtures and 2,500 cubic inches for Table II fixtures. rK|N^|a|C?W"^wjt> #JCzU{Wz8WR+8W}*Kiw9W2_KU2O,gW2Wge,9de}FFx/. For example, you need at least 40 lb for 20 gpm. Ferris, TX 75125 Animal fats and vegetable oils (grease) are 10 to 15 percent less dense than water and will float on top of water. Phone: 419-836-2300. Please take a moment to complete a short survey to provide your input, *For older versions of the Mesa Standard Details and Specifications please contact Engineering-Admin@MesaAZ.gov, M.A.G. Precast concrete grease interceptor tanks are guaranteed water tight and are vacuum tested on-site after installation. Radiant Heating, Snow Melting and Turf Conditioning, USA currently Selected. For example, scullery sinks and meat preparation sinks produce large amounts of grease, oils and solids. Tank, lid and baffles injection molded in engineered thermoplastic that will not corrode, chip, or peel, even under the most severe applications. of Environmental Protection places stringent requirements regarding their use, while carrying out routine inspection for units in operation. Consider that some plumbing fixtures that do not normally receive grease may be exposed to large amounts occasionally: for example, floor drains are not normally exposed to large volumes of grease, but there may be cases where it is spilled on the floor in large amounts and the floor drains must handle it. The triple outlet feature allows for installation flexibility, including the ability to . Partial Inspection #2: Haunched pipe, backfill, cleanout and sampling port shall be inspected prior to pipe backfill. OR_WIL_16x9x8_GreaseInterceptor1000Gallon_266-2.dwg, NE_AVN_4x10x5_1000-Gallon-Grease-Interceptor_27572.pdf, NE_AVN_4x10x5_1000-Gallon-Grease-Interceptor_27572-1.dwg, NE_AVN_6x6x5_1000-Gallon-Grease-Trap_27592.pdf, NE_AVN_6x6x5_1000-Gallon-Grease-Trap_27592-1.dwg, NE_AVN_5x10x5_1500-Gallon-Grease-Trap_27612.pdf, NE_AVN_5x10x5_1500-Gallon-Grease-Trap_27612-1.dwg, NE_AVN_5x10x6_2000-Gallon-Grease-Trap_27632.pdf, NE_AVN_5x10x6_2000-Gallon-Grease-Trap_27632-1.dwg, NE_AVN_6x14x5_5-3-2500-Gallon-Grease-Trap_27652.pdf, NE_AVN_6x14x5_5-3-2500-Gallon-Grease-Trap_27652-1.dwg, NE_AVN_6x14x6_3000-Gallon-Grease-Trap_27672.pdf, NE_AVN_6x14x6_3000-Gallon-Grease-Trap_27672-1.dwg, NE_AVN_6x14x7_4000-Gallon-Grease-Trap_27712.pdf, NE_AVN_6x14x7_4000-Gallon-Grease-Trap_27712-1.dwg, NE_AVN_9x16x6_5000-Gallon-Grease-Trap_27732.pdf, NE_AVN_9x16x6_5000-Gallon-Grease-Trap_27732-1.dwg, VA_FRD_4x8x6_1000-Gallon-Grease-Interceptor_35422.pdf, VA_FRD_4x8x7_1250-Gallon-Grease-Interceptor_35432.pdf, VA_FRD_4x8x8_1500-Gallon-Grease-Interceptor_35442.pdf, VA_FRD_6x12x7_2800-Gallon-Grease-Interceptor_35462.pdf, VA_FRD_6x12x8_3300-Gallon-Grease-Interceptor_35472.pdf, UT_OGD_4x8x6_1250-Gallon-Grease-Trap-Base-w-Lid_41641.pdf, UT_OGD_4x6x3_430-Gallon-Grease-Trap_41651.pdf, FL_CC_6x4x5_ID-750-Gallon-Grease-Trap_43011.pdf, FL_CC_6x4x6_7-0-ID1000-Gallon-Grease-Trap_43021.pdf, Do Not Sell Or Share My Personal Information. Grease Interceptor. Grease interceptors should be installed for any commercial kitchen equipment where grease may be released into drain pipes. P: 713-937-7602Toll Free: 888-611-7275, 8491 Hwy 87 EastSan Antonio, TX 78263P: 210-227-7275, 1200 N Fwy Service Rd The compact design of the GB2 makes it a perfect fit for under-the-sink installations. Precast concrete interceptors shall conform to the . However, wastewater from food preparation contains more oil than in other applications, and the waste from multiple commercial kitchens can overwhelm water treatment systems and cause spillage. Grease Interceptors | Oldcastle Infrastructure Product Availability For more information on product availability call (888) 965-3227 today. It can be installed above grade (on the floor) or buried below grade (compatible with FCR1 riser to bring system to grade). Grease interceptor above ground installation Champion Plumbing 38K views 3 years ago Drain Pros Ep. % EXAMPLE: 1- three compartment sink EXAMPLE: For this reason, they are also known as grease traps. This ensures code compliance, offers hygiene for your staff and customers, and prevents the uncontrolled discharge of grease and oil into the environment. Left and right arrows move across top level links and expand / close menus in sub levels. hbbd```b``f+A$S9d@$&T.@$WX X: "^ IA v8l>#E 3 They are very important for public hygiene, and the NYC Dept. Animal fats and vegetable oils (grease) are 10 to 15 percent less dense than water and will float on top of water. 4 0 obj Table I requires 14 lb of retaining capacity, Table II requires 20 lb of retaining capacity. 454 0 obj <>stream Also consider that the NYC Department of Environmental Protection (DEP) performs routine inspections to ensure that grease interceptors receive proper maintenance and cleaning. Grease interceptors are used in plumbing systems to trap greases, oils and solid particles before they can reach the public sewage. Read about how we use cookies and how you can control them by visiting our Cookie Statement. The new GB-1500 from Schier is the industry's first and only performance-certified 1,500-gallon grease interceptor, offering best-in-class grease capacity achieved by Schier Flow Technology. Grease interceptors are used in establishments to remove excessive amounts of grease that may interfere with the proper drainage and treatment of wastewater. Reinstall the grease trap. 35/50 GPM Hydromechanical Grease Interceptor. Draw-off valve available. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. cHl a4 3030`\ (|0bE^lRL)/8 U? Grease Interceptor - Direct-Bury, Typical Installation Drawing MGT-1. % We also offer tanks for Industrial Waste, PH Adjustment and oil & water separation. Concrete Grease Interceptor Tanks Tanks are reinforced and constructed to ASTM Standards to include C-1613-06. 2nd - divide that by 231 (231 cubic inches = 1 gallon) to get the gallon capacity of the fixture. They must be equipped with vented flow control fittings to keep discharge below the flow capacity specified by the manufacturer. 1 0 obj of Environmental Protection website. For more details on installation and maintenance go to WWW.PDIONLINE.ORG . Gravity Grease Interceptors (GGI), also commonly known as a grease trap, work on the buoyancy principle. Aggregate volume is the maximum volume that can flow through the interceptor simultaneously, determined by adding the wastewater volume of individual fixtures plus any required margins. . However, wastewater from food preparation contains more oil than in other applications, and the waste from multiple commercial kitchens can overwhelm water treatment systems and cause spillage. Condition: New. The tables can be viewed directly in the NYC Dept. According to the estimate, the average cost required to install a grease trap of 10 to 100 gallons is $250 to $1500. Volume-Based Grease Interceptors. P.O. On the other hand, if the grease trap is large, i.e., 750 to 1500 gallons, then the estimated cost required for its installation is between $4000 to $8500. Product Information. 0=>p[0 ! Watts Grease Interceptors are designed to remove grease and similar substances from waste water. Interceptor shall be installed and connected so that it is accessible at all times for inspection, cleaning, and removal of intercepted grease. Protect waste lines against blocking and stoppages. ReWa Grease Interceptor Detail QUESTIONS? Click to change Location. 3 0 obj 5. a#7\*S$S`Rn3aH#{`hf08ClpM9 by\J#'Tm5v"s'. Model #GB-250-FO 100 GPM Grease Interceptor For Indoor/Outdoor Use . Also consider that the NYC Department of Environmental Protection (DEP) performs routine inspections to ensure that grease interceptors receive proper maintenance and cleaning. x=r6?Q' SYUYeU{j}P,YF4oo{7.$s@9I uLF6?W9|vyRyi:iNW*l?3xf?xjyQ G] MFB9G]sV Operation of Grease Interceptors. to trap greases, oils and solid particles before they can reach the public sewage. Clean the trap sides, lids, and parts. Do not install the grease interceptor in a waste line from a garbage grinder. Looking for a quote for your project? Table I still applies. . Page 5: Below Grade Installation Instructions If required, Anchor Plate may be bolted to 45 concrete slab using provided holes. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. Before you Start 1. Typical applications include commercial wastewater, institutional kitchens, and food processing plants.

East Bridgewater News, John Aldridge Hillsborough Nc Obituary, Articles G